o
the device added to the Z-Wave network,
o
parameter 151 is set to 1 or 2.
2. Press and hold UP or DOWN switch for at least 3 seconds
3. Press and hold the same switch again for at least 3 seconds.
4. Press and hold the same switch again for at least 3 seconds.
5. The device will perform the calibration process, completing full cycle – up, down and up
again.
6. Test whether the positioning works correctly.
Calibration using the B-button
1. Make sure:
o
the device is supplied,
o
the device added to the Z-Wave network,
o
parameter 151 is set to 1 or 2.
2. Press and hold the B-button.
3. Wait for the LED to glow white.
4. Quickly release and click the B-button again.
5. The device will perform the calibration process, completing full cycle – up, down and up
again
6. Test whether the positioning works correctly.
Calibration using parameter
1. Make sure:
o
the device is supplied,
o
the device added to the Z-Wave network,
o
parameter 151 is set to 1 or 2.
2. Set the parameter 150 value to 2
3. The device will perform the calibration process, completing full cycle – up, down and up
again
4. The parameter 150 value will be set to 1 after calibration finishes.
5. Test whether the positioning works correctly.
Slats positioning in Venetian blinds mode
Calibration using a connected momentary switch
1. Make sure:
o
the device is supplied,
o
the momentary switch is connected to S1 and S2 terminals,
o
the device added to the Z-Wave network,
o
parameter 151 is set to 2,