#7: Configurable parameters

1. Type of connected switch
This parameter allows to select type of wall switch connected to the
device.
Available settings: 0 – momentary switch
Default setting:
2. Restore state after power failure
This parameter determines if the device will return to state prior to
the power failure after power is restored.
Available settings: 0 – the device does not save the state prior to
Default setting:
1 – toggle switch (contact closed - On, contact
opened - OFF)
2 – toggle switch (device changes status when
switch changes status)
1 (toggle switch - synced)
the power failure and sets „off" position
1 – the device does not save the state prior to
the power failure and sets „on" position
2 – the device restores its state prior to the
power failure
2 (state is restored)
i
NOTE
If parameter 1 is set to
1, parameter 2 is irrel-
evant and device state
is always the same as
switch state.
COnFIGuRABlE PARAMETERS