Lower Both Uplink and Downlink
IHU RF Levels
The IHU downlink has a high gain to boost weak received signals to levels to drive
the optical components. Do not allow a composite RF level greater than 0 dBm into
the optical transceiver. See the IHU rear RF INPUT MAX information. Uplink power
settings can be done as the RRU instructions.
RRU RF power Considerations
The RRU is available with many RF power outputs. For each product, there are
considerations for pad power dissipation. Product power levels are the Output P1 dB
compression point.
Model Series
FS31RX-A, ½ Watt
FS31RX-B, 1 Watt
FS31RX-C, 5 Watt
FS31RX-D, 10 Watt
FS31RX-E, 20 Watt
Table 2. Attenuator Power Dissipation Recommendations For Attenuator A or D
RRU Photographs
Page 10 of 13
Table 1. Attenuator Configurations
Minimum Attenuator Dissipation
1 Watt
2 Watts
10 Watts
20 Watts
50 Watts
Rev 01 5-DEC-06
Maximum Composite RF
into LNA (No Damage) +10
dBm, input P1 = -6 dBm,
LNA gain is 27 dB
Pad C N-
External in-line attenuator
Female to N-
Male
Fiber Optic RF Repeater System