Fiber-Span FS31 Series 사용자 설명서 - 페이지 12
{카테고리_이름} Fiber-Span FS31 Series에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Fiber-Span FS31 Series 16 페이지. Fiber optic rf repeater system
6.3.1 Recommended System Start up Procedure
• Verify all RF cables are connected and all unused RF connections terminated with
50 Ohm terminations.
• Verify all Alarm and AC connections are properly made
• Connect fiber optic cables.
• Apply AC power to system components.
6.4 Caution
RRU has internal AC power connections that can cause shock if operator is not
careful. Always verify the AC Power area is clear of all objects. Do not leave
objects inside the RRU that can cause dangerous shock hazard.
7
Maintenance
This Fiber Optic repeater system does not require scheduled maintenance.
However, use precautions while installing optical fibers to keep connector surfaces
clean. An unclean optical connector surface can damage the internal transceiver
connector which can degrade system performance and violate Fiber-Span warranty.
Keep heat dissipating surfaces or vents clean and clear.
8
Company Information
Fiber-Span designs and manufactures fiber optic modules and systems used in the
transmission and distribution of RF and wireless signals. Fiber-Span's fiber optic
transmitters, receivers and transceivers are widely used in wireless and RF systems
worldwide by wireless systems OEM's, systems integrators and military systems
designers to capitalize on the inherent advantages of fiber. Fiber has extremely low
RF attenuation (< 1dB/km), very high bandwidth, immunity to EMI, no signal egress,
flat broadband delay characteristics plus a cable design that is light weight and
small size.
Fiber-Span
111 Corporate Blvd.
South Plainfield, NJ 07080
USA
908-754-0646
908-754-0647 FAX
Internet
http://www.fiber-span.com
Page 12 of 13
Rev 01 5-DEC-06
Fiber Optic RF Repeater System