Sharp 21HT-16CS 서비스 매뉴얼 - 페이지 11
{카테고리_이름} Sharp 21HT-16CS에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Sharp 21HT-16CS 44 페이지. Pal secam b/g, d/k system colour television
• Colour adjustment procedure
The following adjustments should only be carried out when the CRT or IC801 are replaced.
Notes:
•
This adjustment must be done after warming up the unit for 30 minutes or longer with a beam current over 700 µA.
•
The red value «DRI-RS» should be fixed to 42. (Refer to "How to access service mode" section).
•
«DRI-GS» adjustment alters "Y" coordinate.
•
«DRI-BS» adjustment alters "X" and "Y" coordinates.
Adjustment method 1 (using the signal generator, varying the picture signal)
1. Adjust G2.
2. Input a white pattern with burst signal from SCART.
3. Position the colorimeter in the centre of screen.
4. Adjusting input signal level, select a luminance of 70 nits.
5. Operate again in "service mode" and select «DRI-GS» and/or «DRI-BS» locations to obtain colour coordinates:
6. Reset the T V with the mains switch button to store the adjustment and exit service mode.
7. Check colour coordinates "X" and "Y" at 20 a 120 Nits. It may be necessary to repeat the same procedure to
obtain the above values.
Adjustment method 2 (using the signal generator, with a fixed picture signal)
1. Adjust G2.
2. Tune a white pattern with burst signal.
3. Operate in "service mode":
4. Using «SUB-CON», select a luminance of 70 nits.
5. Operate again in "service mode" and select «DRI-GS» and/or «DRI-BS» locations to obtain colour coordinates:
6. Select «SUB-CON». Return data to "63".
7. Reset the TV with the mains switch button to store the adjustment and exit service mode.
8. Check colour coordinates "X" and "Y" at 20 a 120 Nits. It may be necessary to repeat the same procedure to
obtain the above values.
X
0.304 + 0.015
0.306 + 0.015
X
0.304 + 0.015
0.306 + 0.015
Y
Screen temperature
7250º K-11 MPCD
Y
Screen temperature
7250º K-11 MPCD
11
21HT-15C
21HT-16C