Digital Aquatics ReefKeeper 사용자 설명서 - 페이지 15

{카테고리_이름} Digital Aquatics ReefKeeper에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Digital Aquatics ReefKeeper 18 페이지.

to no more than three degrees below the fan/chiller turn-off temperature on the ReefKeeper. This will allow redundant
protection from a single-point failure.
If you set the channel to be always on, it will act as regular power outlet, with no switching.
If you set the channel to be always off, there will be no power to that channel. It is recommended that you set unused
channels to this setting.

Setup Wavemaker

Every channel that is set to be a powerhead is associated with one cycle: A, B, or C. The A and B cycles alternate at the
set interval. The C cycle turns on and off at the set interval but is independent of the A and B cycles.
In the Setup Wavemaker menu, you must first set the Cycle A/B time. This is the amount of time that cycle A will be on
while cycle B is off and vice versa. You may set this time to any value between 20 seconds and 4 hours. Once you have
made your selection, you must set the Cycle C time. This is the amount of time that cycle C will be on and off for in
succession. You may set this time to any value between 20 seconds and 2 hours.
Night mode occurs when all the lights are off based on the configuration of the light channels. During night mode the
powerheads that are configured to be off turn off and A/B and C cycle times double.
The currently active wavemaker cycles are displayed on screen, as shown at right
with the 'A' and 'C'.
15
6/28/2005
www.DigitalAquatics.com