3. Identify the two field windings on the motor.
wire, while the other is an orange color.
which, and connect it to the GRN LCRU wire.
should be wrapped with electrical tape.

Connecting Power Leads

Depending upon the locomotive, it will have either one or two power collectors, a dual roller
collector mounted on the front truck, or a single roller type mounted on both the front and rear
trucks.
In either case, the connection procedure is the same, but must be repeated for
locomotives equipped with two single roller collectors.
1. Locate the wire(s) coming from the power pickup roller(s).
2. Using a pair of cutters, clip off a small amount of the exposed wire to remove all old
solder from the strands.
3. Strip the insulation back so that you have approximately 3/8" of clean, exposed wire.
Using one of the supplied wire nuts, twist together the wire(s) coming from the pickup roller(s)
together with the Pink power lead from the LCRU circuit board.
short as possible without their interfering with truck movement.

Diecast Steam Engines

Diecast Steam Engines
Electrical connections from the tender mounted LCRU to the engine are made through an eight-pin
connector assembly available from Digital Dynamics.
1. Remove the shell from the tender and place it aside where it cannot be damaged.
chassis on a clean, level work surface.
2. Disconnect the wires from the whistle relay to the whistle motor.
3. Remove the wires connecting the whistle motor to the pickup rollers.
4. Remove the whistle motor by unfastening the nuts from underneath the chassis.
5. Remove the two screws located at the base of the Relay Bracket.
6. Clean any grease, oil, or loose rust from the chassis surface.
7. Attach the LCRU to the tender chassis using the supplied foam adhesive tape.
to the LCRU in the same pattern shown in the previous section.
8. Feed the wires from the 8-pin MALE connector through an opening in the engine side of the
tender.
The MALE connector is the one with the seven equal length wires attached.
Lionel tenders have an opening to allow air to enter the air whistle.
9. Make all LCRU connections for headlamp, smoke unit, motor, power and chassis ground to the
wires of the connector assembly.
connections.
10. Connect the Black programming wire located adjacent to the wires leading to the PROG/RUN
switch, to chassis ground.
in the back of this manual for reference.
Select one of the coils, it makes no difference
Use the wire nuts enclosed with the kit to make the
Refer to the diagram below, and the Steam Wiring Diagram located
Figure 3. Steam Connector - Tender Side
One of the coils is wound in green colored
The other coil is not connected and its end
Remember to keep the wires as
LCRU Installation Manual
© Digital Dynamics
Place the
Apply the tape
Most
8