3

General Specifications

Electrical
Input Voltage
Rated Voltage
Frequency
Allowable Voltage Drop
Power Consumption
In-Rush Current
Voltage Endurance
Insulation Resistance
Environmental
Ambient Operating
Temperature
(Cabinet interior and exterior)
Storage Temperature
Ambient Humidity
Air Purity Level
Atmosphere
Vibration Resistance
Noise Endurance
(via noise simulator)
Structural
Grounding
Rating
Cooling Method
Weight
External Dimensions
*1 The front face of the PL unit, installed in a solid panel, has been tested using conditions equivalent to
the standard shown in the specification . Even though the PL unit's level of resistance is equivalent to
the standard, oils that should have no effect on the PL can possibly harm the unit. This can occur in
areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to
adhere to the unit for long periods of time. If the PL's front face protection sheet becomes peeled off,
these conditions can lead to the ingress of oil into the PL and separate protection measures are
suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front
panel's plastic cover. Therefore, prior to installing the PL be sure to confirm the type of conditions
that will be present in the PL's operating environment.
If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from
the panel, the original level of the protection cannot be guaranteed. To maintain the original protec-
tion level, you need to replace the installation gasket regularly.
0.1mg/m
19.6m/s
Less than 100 Ω , or your country's applicable standard.
*1
W 405mm [15.94in.] x H 350mm [13.78in.] x D 74mm [2.91in.]
AC 100V to AC 240V
AC 85V to AC 265V
50/60Hz
1 cycle or less
65VA or less
30A (normal), 45A (40
AC 1500V at 20mA for 1 minute
(between charging and FG terminals)
Greater than 10M Ω at DC 500V
(between charging and FG terminals)
o
0
C to 40
o
-10
C to 60
30% RH to 85% RH (no condensation)
3
or less (free of conductive particles and dust)
800 to 1114hPa (2000 meters or lower)
2
at 10Hz to 25Hz in X, Y, Z directions for 30 minutes
Noise Voltage: 1500Vp-p
Pulse Width: 50ns, 500ns, 1 µ s
Rise Time: 1ns
Exclusive grounding only:
Equivalent to IP65f (JEM1030)
Via natural cooling
Less than 6.5kg (14.3lb)
(with HDD and FDD installed)
(excluding projections)
- 6 -
o
C)
o
C
o
C