Wiring Standard
Maximum Distance
Isolation
a
Auto-negotiating.
b
Shielded or unshielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
5.5

Fiber Optic Ethernet Port Specifications

The following details the specifications for fiber Ethernet ports that can be ordered
with the RUGGEDCOM RS900F.
Note
Connector
Mode
Type
MM
MTRJ
MM
SC
MM
ST
MM
LC
SM
ST
SM
LC
SM
LC
SM
LC
SM
SC
SM
SC
SM
SC
a
Typical.
RUGGEDCOM RS900F
Installation Manual, 04/2021, C79000-G8976-1350-07
c
TIA/EIA T568A/B
d
100 m (328 ft)
e
2.5 kV
All optical power numbers are listed as dBm averages. To convert from average
to peak, add 3 dBm. To convert from peak to average, subtract 3 dBm.
Maximum segment length is greatly dependent on factors such as fiber quality,
and the number of patches and splices. Consult a Siemens sales associate when
determining maximum segment distances.
Tx λ
Cable
a
(nm)
Type (μm) Minimum Maximum
50/125
1300
62.5/125
50/125
1300
62.5/125
50/125
1300
62.5/125
1310
62.5/125
1310
9/125
1300
9/125
1310
9/125
1310
9/125
1300
9/125
1310
9/125
1310
9/125
5.5 Fiber Optic Ethernet Port Specifications
Tx (dBm)
Sensitivity
(dBm)
-22.5
-14
-33.5
-19
-14
-33.5
-22.5
-14
-33.9
-19
-14
-33.9
-22.5
-14
-33.9
-19
-14
-33.9
-19
-14
-15
-7
-15
-8
-5
0
0
5
-15
-8
-5
0
5
0
Technical Specifications
Rx
Rx
Distance
Saturation
(km)
(dBm)
-14
-14
-14
-14
-14
-14
-32
-14
-34
-3
20
-38
-3
20
-35
-3
50
-37
0
90
-31
-7
20
-34
-3
50
-37
0
90
Power
Budget
a
(dB)
2
11
2
14.5
2
11.4
2
14.9
2
11.4
2
14.9
2
13
19
23
30
37
16
29
42
29