Siemens SIMATIC NET RUGGEDCOM RS1600 설치 매뉴얼 - 페이지 18
{카테고리_이름} Siemens SIMATIC NET RUGGEDCOM RS1600에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Siemens SIMATIC NET RUGGEDCOM RS1600 42 페이지. Rugged ethernet switches
Siemens SIMATIC NET RUGGEDCOM RS1600에 대해서도 마찬가지입니다: 설치 매뉴얼 (42 페이지)
2.3.1
Mounting the Device to a Rack
For rack mount installations, the RUGGEDCOM RS1600 can be equipped with rack
mount adapters pre-installed.
Note
The chassis features multiple mounting holes, allowing the rack mount adapters to
be installed up to 25 mm (1 in) from the face of the device.
To secure the device to a standard 48 cm (19 in) rack, do the following:
1.
2.
3.
2.3.2
Mounting the Device on a DIN Rail
For DIN rail installations, the RUGGEDCOM RS1600 can be equipped with panel/DIN
rail adapters pre-installed on each side of the chassis. The adapters allow the device
to be slid onto a standard 35 mm (1.4 in) DIN rail.
RUGGEDCOM RS1600
Installation Manual, 11/2022, C79000-G8976-1013-04
Make sure the rack mount adapters are installed on the correct position on the
chassis.
1
Rack Mount Adapter
1
Figure 2.1
Rack Mount Adapters
Insert the device into the rack.
Note
Since heat within the device is channelled to the enclosure, it is recommended
that 1 rack-unit of space, or 44 mm (1.75 in), be kept empty above the device.
This allows a small amount of convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a
reduction of ambient temperature and improve the long-term reliability of all
equipment mounted in the rack space.
Secure the adapters to the rack using the supplied hardware.
Installing Device
2.3.1 Mounting the Device to a Rack
1
9