Emergency stop button
Rated voltage
Current rating, max.
Current rating, min.
Switching capacity
Conditional rated short-circuit current
B
10d
Note
The quantitative assessment of the emergency stop safety function must be based on the B
values corresponding to the used standards (e.g. ISO 13849-1) under consideration of the
respective application (frequency of the actuation, service life, diagnostics by the evaluation
unit, etc.). The B
button are taken into account.
ONE MCP Part 2: MCP 1900.2
Equipment Manual, 01/2023, A5E52559449B AA
values only apply when the technical properties of the emergency stop
10d
24 V DC
3 A
1 mA
DC 13 according to EN 60947-5-1
10 A gL/gG according to EN 60947-5-1
500000
Technical data
10d
23