Siemens SINUMERIK ONE MCP 1900.2 Equipment Manual - Page 23

Browse online or download pdf Equipment Manual for Industrial Equipment Siemens SINUMERIK ONE MCP 1900.2. Siemens SINUMERIK ONE MCP 1900.2 26 pages.

Emergency stop button
Rated voltage
Current rating, max.
Current rating, min.
Switching capacity
Conditional rated short-circuit current
B
10d
Note
The quantitative assessment of the emergency stop safety function must be based on the B
values corresponding to the used standards (e.g. ISO 13849-1) under consideration of the
respective application (frequency of the actuation, service life, diagnostics by the evaluation
unit, etc.). The B
button are taken into account.
ONE MCP Part 2: MCP 1900.2
Equipment Manual, 01/2023, A5E52559449B AA
values only apply when the technical properties of the emergency stop
10d
24 V DC
3 A
1 mA
DC 13 according to EN 60947-5-1
10 A gL/gG according to EN 60947-5-1
500000
Technical data
10d
23