Siemens SIWAREX R 사용 설명서 - 페이지 27

{카테고리_이름} Siemens SIWAREX R에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Siemens SIWAREX R 38 페이지. Mounting units for sb series
Siemens SIWAREX R에 대해서도 마찬가지입니다: 사용 설명서 (34 페이지)

Siemens SIWAREX R 사용 설명서
Revision 09/04
5.
Setting the overload protection:
Load the loading platform with the
maximum applicable load.
Set the overload protection
mechanism (11) in connection with
the nut (10) to 0.05 - 0,1 mm, see
dimension X in Fig. 3-3
Dimension X must also exist after
tightening the nut (10).
DANGER
Contaminated, icy or incorrectly set overload protection will create blockages
which cause incorrect measurements or can cause injury or damage to the
machinery by overloading the scale.
6.
Assembly Inspection:
• The loading platform must be
able to swing freely.
• The countersunk bolts (9) should
be positioned as close to the
middle of the holes in the top
plate (18) as possible. The top
plate therefore has optimal
freedom of movement on all sides
and no secondary forces can be
generated.
• The countersunk bolts (9) must not
protrude past the top plate (18).
DANGER
Incorrectly adjusted counter-sunk bolts cause blockages which in turn result in
incorrect measurements or can lead to overloading the scale and damage to
equipment or injury to persons.
Document No.: A5E00353789B
Comb. Mounting Units
Fig. 3-3 Setting the overload
protection
Fig. 3-4 Overload Protection and
oscillation limitation
Page 27