Siemens SIWAREX WL230 BB-S SA 사용 설명서 - 페이지 23

{카테고리_이름} Siemens SIWAREX WL230 BB-S SA에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Siemens SIWAREX WL230 BB-S SA 44 페이지. Base plate and elastomer bearing bb-s sa
Siemens SIWAREX WL230 BB-S SA에 대해서도 마찬가지입니다: 매뉴얼 (36 페이지), 사용 설명서 (48 페이지), 장비 매뉴얼 (50 페이지)

Siemens SIWAREX WL230 BB-S SA 사용 설명서
Figure 4-1
1. Place the elastomer bearing
2. Hold the elastomer bearing.
Holding the elastomer bearing prevents damage to the load cell.
3. Screw the hexagon screw
elastomer bearing.
Figure 4-2
4. Place the load cell on the base plate using the spacing strip to match the holes.
5. Position the washers.
6. Insert the screws with washers.
7. Tighten the screws to the specified tightening torque (Page 33).
You will avoid damaging the load cell by not counter-tightening the load cell.
4.2.6

Install the load cell with elastomer bearing unit

Installation requirements
● Flatness of the mounting surfaces: A plane of ≤ 0.2 mm is required for the mounting
surfaces.
● Compressive strength of the mounting surfaces: The compressive strength of the mounting
surfaces has to be appropriate for the contact surface pressure of the base plate and
elastomer bearing.
BB-S SA
Operating Instructions, 03/2020, A5E47358100-AA
Install the elastomer bearing in the load cell
over the load cell support
(optionally with washer (Page 7)) into the load cell and
Mounting the elastomer bearing and load cell on the base plate
4.2 Installing the base plate and elastomer bearing
.
Installation
23