CF-001
Fault Code CF-001, indicates that the feed motor (CF-M15) has a Short circuit.
Initial Actions
Check fuse F2 on Transformer.
Procedure
Disconnect the motor plug M15. Run the SDS again. Fault code CF-002 (Open circuit) is displayed?
Y
N
Disconnect plug H.P2 from PCB "H". Check wires for Short circuit across leads, the orange wire M15 to H.P2-10
(violet) and the violet wire M15 to H.P2-3 (orange). Is there Short circuit?
Y
N
Replace PCB "H".
Replace wire Harness.
Replace motor CF-M15.
CF-002
Fault Code CF-002, indicates that the feed motor (CF-M15) has an Open circuit.
Initial Actions
Check fuse F2 on Transformer.
Procedure
Disconnect the motor plug M15. Enter Service mode and start feed motor (CF-M15) in check motors. Measure between the
orange wire M15 and the violet wire M15 (PWM 36V and ground). The voltage is approximately 36 VDC?
Y
N
Disconnect plug H.P2 from PCB "H". Measure between J2-3 and J2-10 (PWM 36V and ground). The voltage is
approximately 36 VDC?
Y
N
Replace PCB "H".
Replace wire Harness.
Replace motor CF-M15.
CF-003
Fault Code CF-003, indicates that the feed motor (CF-M15) does not receive any displacement
pulses.
Initial Actions
Check fuse F2 on Transformer.
Enter the Service mode and select feed motor (CF-M15) in check motors.
Procedure
Disconnect the sensor plug Q28 to motor CF-M15. Measure between the red wire Q28 and the black wire Q28 (5V and Signal
ground). The voltage is approximately 5 VDC?
Y
N
Disconnect plug F.P6 from PCB "F". Measure between the J6-18 and J6-19 (5V and Signal ground). The
voltage is approximately 5 VDC?
Y
N
Replace PCB "F".
Replace wire harness.
Disconnect plug F.P6 from PCB "F". Check wires for Continuity / Short circuit from the white wire Q28 to F.P18-18,
the black wire Q28 to F.P18-19, the red wire Q28 to F.P18-4. Is there Continuity and no Short circuit?
Y
N
Replace wire harness.
1. Replace motor CF-M15.
2. Replace PCB "B".
CF-4-2