6
SERIES 900 SMART PROGRAMMABLE RELAYS
PROGRAMMING AT THE DEVICE: MENU & FUNCTIONS
Screen 1
WE DIDN'T INVENT CONTROL, WE'RE PERFECTING IT.
Screen 2
Screen 6
Screen 7
Screen 8
Screen 9
Screen 3
Screen 4
Screen 5
Screen 10
Screen 11
EXPANSION
Screen 12
Screen 13
Programming and other settings in the Series 900 relay can be done using the
software as well as on the device itself with the help of the backlit display and keypad.
When the connections are made and the device is powered ON, screen 1 is displayed
on the device. By default the cursor will blink on the 'PROGRAM' option. Using the Up/
Down keys, user can select between any of the options.
When the cursor is on the PROGRAM option and OK key is pressed, then screen 2 is displayed.
When screen 2 is being displayed, the cursor is on the 'EDIT' option.
Press the OK key to enter this option and screen 6 will be displayed. Similarly
by pressing the Down key and OK, one can enter the other functions: "DELETE",
"TRANSFER", "MODBUS CONF", and screens 7, 8, and 9 will be displayed respectively.
EDIT
This function allows the user to enter a new program or edit an existing program. If
password is set, then this function is accessible only with the correct password.
DELETE
This function will clear the entire program stored in the Series 900 relay. If password is
set, then this function will work only with correct password.
TRANSFER
This function will transfer the program from device to memory card or vice versa.
Program data on memory can also be deleted in this mode.
MODBUS CONF
This function will set Modbus Slave configuration data.
The user can set the following communication parameters:
• SLAVE ID, BAUD RATE, PARITY, STOP BIT
When screen 1 is being displayed, press the Down key to shift the cursor to the RUN
option and press the OK key to enter it. Screen 3 will be displayed.
RESET
The RESET mode resets all the previous states of inputs/outputs, clears timer and
counter states, and starts afresh.
CONTINUE
The CONTINUE mode does not change the states of the inputs/outputs and special
functions and continues with the execution of the program.
When the cursor is on the PARAMETERS option and OK is pressed then screen 4 will be
displayed.
PARAMETERS
This function displays and allows the user to change parameters of special functions
like timer, counter, time switch (clock), compare counters and analog functions used in
the program. This may be password protected and may have additional individual lock
for each parameter.
When the cursor is on the UTILITIES option and OK key is pressed, then screen 5 is
displayed.
When screen 5 is being displayed, the cursor is on the 'SET CLOCK' option.
Press the OK key to enter this option and screen 10 will be displayed. Similarly by
pressing the Down key and OK, one can enter the other functions: "PASSWORD", "EXT
MOD", "BACKLIT CONF", and screens 11, 12, and 13 will be displayed respectively.
SET CLOCK
This function is used to set the day and time: Day of the week, Date, Hours-Minutes.
This function is available only on the Series 900 relay unit.
PASSWORD
This function allows setting of password. If password is set, certain functions like
Program and Parameters are protected and are accessible only when correct password
is entered. The Password can be set or removed; the status is indicated by the open or
closed lock symbol.
EXPANSION MODULE (EXT MOD)
This function allows the selection of the Expansion Modules (A/B/C). Maximum of three (3)
Expansion Modules can be connected to the Series 900 relay main unit. In the SPR-soft III
on PC, expansion modules have to be chosen using the "Configuration" menu.
BACKLIT CONF
This function allows the setting of backlight in either ON, OFF, or AUTO mode. In the
AUTO mode, the backlight comes up only when a key is pressed on the device and
remains for 10 seconds. If the ON or OFF modes are selected the backlight will be
permanently ON or OFF respectively.