c3controls 900-SBA8I4OM 사용 설명서 - 페이지 8

{카테고리_이름} c3controls 900-SBA8I4OM에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. c3controls 900-SBA8I4OM 17 페이지. Smart programmable relays

8
SERIES 900 SMART PROGRAMMABLE RELAYS
FUNCTIONS
SETTING THE CLOCK
1. Select the "UTILITIES" option from the main menu and press OK.
2. Select the "SET CLOCK" option from the sub menu and press OK.
3. The cursor will blink on the first digit of the date, press ALT to edit the digit.
4. The digit will now start blinking.
5. Using Up (Z4) and Down (Z2) keys select the appropriate digit.
6. Now press Z3 to edit the other digit and using Up and Down keys select the digit.
7. Now press OK to confirm the changes that have been made.
8. Repeat the same procedure to set the month, year, hour and minutes.
9. Once all the parameters have been set, press OK to save the changes and exit.
PROGRAM
SET CLOCK
OK
RUN
PASSWORD
PARAMETERS
EXT MOD
UTILITIES
BACKLIT CON
DD/MM/YY
DD/MM/YY
Z3
11/01/11
11/01/11
HH:MM
HH:MM
09:30
09:30
PASSWORD
The password secures access to the following main menu options:
"PROGRAM", "PARAMETERS", and "UTILITIES".
In RUN mode password protects the run time parameters and ladder viewing.
The password comprises four numeric digits from 0 to 9. Therefore the
password can have any value between 0 and 9999.
SETTING THE PASSWORD
1. Select the "UTILITIES" option from the main menu and press OK.
2. Select the "PASSWORD" option from the sub menu and press OK.
3. The unlock symbol means that the password is not yet set.
4. The cursor will blink on the first digit of the date, press the ALT key to edit
the digit.
5. The digit will now start blinking.
6. Using Up (Z4) and Down (Z2) keys select the appropriate digit.
7. Now press Z3 to edit the other digit and using the Up and Down keys
select the digit.
8. Press OK to confirm the password.
9. Press OK again to enable the password and return to the main menu.
PROGRAM
SET CLOCK
OK
RUN
PASSWORD
PARAMETERS
EXT MOD
UTILITIES
BACKLIT CON
PASSWORD
PASSWORD
OK
7 2 5 7
7 2 5 7
REMOVING THE PASSWORD
1. Select the "UTILITIES" option from the main menu and press OK.
2. Select the "PASSWORD" option from the sub menu and press OK.
3. The lock symbol means that the password is set.
4. The cursor will blink on the first digit, press ALT to edit the digit.
5. The digit will now start blinking.
6. Using Up (Z4) and Down (Z2) keys select the appropriate digit.
7. Now press Z3 to edit the other digit and using Up and Down keys
select the digit.
8. Repeat the same procedure to set all 4 digits.
9. Now press OK to confirm the changes that have been made.
10. Pressing OK again, the password is disabled and the main menu is
displayed.
PROGRAM
SET CLOCK
OK
RUN
PASSWORD
PARAMETERS
EXT MOD
UTILITIES
BACKLIT CON
PASSWORD
PASSWORD
OK
7 2 5 7
7 2 5 7
WE DIDN'T INVENT CONTROL, WE'RE PERFECTING IT.
DD/MM/YY
DD/MM/YY
OK
ALT
01/01/11
01/01/11
HH:MM
HH:MM
09:30
09:30
DD/MM/YY
SAVING DATA
Z4
15/01/11
. . . WAIT
HH:MM
09:30
PASSWORD
PASSWORD
ALT
Z4
7
PROGRAM
PASSWORD
OK
RUN
ENABLED
PARAMETERS
UTILITIES
PASSWORD
PASSWORD
ALT
Z4
7
PROGRAM
PASSWORD
OK
RUN
ENABLED
PARAMETERS
UTILITIES
EXPANSION MODULE SELECTION
1. Select the "UTILITIES" option from the main menu and press OK.
2. Select the "EXT MOD" option from the sub menu and press OK.
3. The cursor will be blinking on 'A' , press ALT to edit and the 'A' will start
blinking.
4. Press Up (Z4) or Down (Z2) keys to select or deselect the expansion module.
5. A dark square around 'A' indicates that the module has been selected.
6. Now press OK to confirm the changes that have been made.
7. Repeat the same procedure if the other modules are to be selected.
8. Press OK to save the changes and the 'UTILITIES' sub menu is displayed.
PROGRAM
Z4
OK
RUN
PARAMETERS
UTILITIES
EXTENSION
MODULES
A
B
C
If only one expansion (extension) module is being used and it has been
assigned as 'A' on the expansion module using the selection switch then
make sure that 'A' is selected in the 'EXT MOD' option in the 'UTILITIES'
menu. If more than one expansion module is being used then make sure
that the modules have been assigned and selected appropriately because
this in turn will affect the inputs and the outputs.
BACKLIT CONFIGURATION
1. Select the "UTILITIES" option from the main menu and press OK.
2. Select the "BACKLIT CONFIG" option from the sub menu and press OK.
3. The 'AUTO' option will be displayed with the cursor blinking on it.
4. Press ALT to edit and the AUTO option will start blinking.
5. Press Up (Z4) or Down (Z2) keys to select other options: ON, OFF.
6. Now press OK to confirm the changes that have been made.
7. Press OK to save the changes and the 'UTILITIES' sub menu is displayed.
PROGRAM
RUN
OK
PARAMETERS
UTILITIES
BACKLIT
OK
CONFIG
ON
AUTO: In AUTO mode, whenever a key is pressed the backlight will be
switched ON and will switch OFF after 10 seconds.
ON:
In ON mode, the backlit will be permanently switched ON.
OFF:
In OFF mode, the backlit will be permanently switched OFF.
PROGRAM PROTECTION
1. If the password is already enabled and user attempts to gain access using
wrong password, then an error message is displayed.
2. If four such consecutive attempts are made then user is presented with
options to either delete the entire device data or else revert.
3. If the DELETE ALL option is selected, then all device data including Password
and program are erased. The user can then reprogram using SPR Soft
software and secure it with a new password.
After four wrong attempts of entering the Password the Screen as shown below
appears. Pressing OK here will delete all device data or press ESC to return to
previous screen (pressing ESC will not delete).
PASSWORD
SET CLOCK
EXTENSION
OK
ALT
PASSWORD
MODULES
EXT MOD
BACKLIT CON
A
B
C
SAVING DATA
SET CLOCK
. . . WAIT
PASSWORD
EXT MOD
BACKLIT CON
SET CLOCK
BACKLIT
PASSWORD
OK
CONFIG
ALT
EXT MOD
BACKLIT CON
AUTO
BACKLIT
SAVING DATA
CONFIG
OK
. . . WAIT
ON
PASSWORD
INVALID
OK
PASSWORD
. . . try later
DELETE ALL?
INITIALIZING
OK
OK
DEVICE DATA
. . . WAIT
EXTENSION
Z4
MODULES
A
B
C
BACKLIT
CONFIG
Z4
AUTO
SET CLOCK
PASSWORD
EXT MOD
BACKLIT CON