Alarm Management
• TIM -
• ODUk-TIM-PM -
• OTUk-SF -
• SF-L -
If the condition does not clear, log into the Technical Support Website at
index.html

DISK-SPACE

Default Severity: Minor ( when 80% of disk space is full) , Major ( when 90% of disk space is full) and Critical
(when 95% of disk space is full).
Logical Object: None
DISK-SPACE alarm is generated for "/misc/disk1", "/misc/scratch", "/var/log/", "/" filesystems on the admin
nodes. The alarm occurs when the disk space on the file system is low with respect to the configured threshold
values.

Clear the DISK-SPACE Alarm

Procedure
Clear the unwanted files on the corresponding filesystem.
If the condition does not clear, log into the Technical Support Website at
support/index.html

EJECTOR-FLAPS-OPEN

Default Severity: The default severity depends on the card type.
• For route processor cards - Major, NSA (Non-service affecting)
• For line cards - Major, SA (Service affecting)
• For fabric cards - If one FC is down/ removed, the alarm is minor and NSA; if more than one FC is down,
Logical Object: EQPT
Clear the TIM Alarm, on page 25
Clear the ODUk TIM PM Alarm, on page 18
Clear the OTUk SF Alarm, on page 21
Clear the SF-L Alarm, on page 23
for more information or call Cisco TAC (1 800 553-2447).
for more information or call Cisco TAC (1 800 553-2447).
the alarm is major and SA.