Clear the EJECTOR-FLAPS-OPEN Alarm
Clear the EJECTOR-FLAPS-OPEN Alarm
Procedure
For RP, remove the card and replace. For fabric cards and line cards, close the ejector flaps.
If the condition does not clear, log into the Technical Support Website
support/index.html
FC-REDUNDANCY-LOST
Default Severity: Major (MJ) or Critical (CR), Non-Service-Affecting (NSA), or Service-Affecting (SA)
Logical Object: PORT
The Fabric Card Redundancy alarm occurs when one or more than one fabric card is removed.
Clear the FC-REDUNDANCY-LOST Alarm
Procedure
Either plug in 3 or all 4 fabric cards.
If the condition does not clear, log into the Technical Support Website
support/index.html
FEC-MISM
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Object: PORT
FEC Mismatch alarm occurs when there is a FEC configuration mismatch in a span.
Clear the FEC MISM Alarm
Procedure
Step 1
Check the configured FEC type on the controller and the connected port.
Step 2
This alarm is triggered, when the FEC type of the controller and the connected port are different. Set the same
FEC type for the controller and the connected port.
The available FEC types are: