Figure 2
Pivot the two module ejector levers out and away from the faceplate.
Step 7
Carefully slide the supervisor engine into the slot until the notches on both ejector levers engage the
Step 8
chassis sides.
Using the thumb and forefinger of each hand, simultaneously pivot in both ejector levers to fully seat the
Step 9
supervisor engine in the backplane connector.
Caution
Always use the ejector levers when installing or removing a supervisor engine. A supervisor engine that
is partially seated in the backplane will not function correctly.
Use a screwdriver to tighten the captive installation screws on each end of the supervisor engine
Step 10
faceplate.
To check the status of the module, follow these steps:
Ensure that the LED labeled Status is green (module operational).
Step 1
When the switch is online, enter the show module command. Verify that the system acknowledges the
Step 2
new module and that the module's status is good.
If the module is not operational, reseat it. If the module is still not operational, contact your customer
Step 3
service representative.
78-18337-01
Installing the Supervisor Engine in the Chassis (Catalyst 4506-E Shown)
45 06
Installation and Configuration Note for the Catalyst 4500 E-Series Supervisor Engine 6-E
Removing the Supervisor Engine