To ensure proper performance of the DL-HD2100, it is recommended that you use solid core
Category 6 F/UTP cabling at a minimum. Category 5e F/UTP may perform well but may not
support power over HDBaseT reliably.
For opti mized performance use the following Liberty Wire and Cable branded cabling;
1
8
RS232 Wiring
Connect the controller or device RXD signal
to Tx on the DL-HD2100 extender. Connect
the controller or device TXD signal to Rx on
the DL-HD2100 extender.
DL-HD2100
(TX/RX)
Tx
Rx
Cabling Requirements
When using shielded category cabling ALWAYS...
....use shielded connectors
....properly ground the category cable
Category 6 plenum; 24-4P-P-L6SH
Category 6 NON-plenum; 24-4P-L6SH
Category 6A plenum; 24-4P-P-L6ASH
Category 6A NON -plenum; 24-4P-L6ASH
TIA/EIA-568B
P n 1
Or n e/Wh te
P n 2
Or n e
P n 3
Green/Wh te
P n 4
P n 5
Blue/Wh te
P n 6
Green
P n 7
Brown/Wh te
P n 8
Brown
Controller or
Device
RXD
TXD
GND
Twisted Pair Wiring
Use TIA/EIA-568B wiring for Category 6
Blue
connecti on between send and receive
units.