HDBaseT Connection
Connect one end of a Category cable to the DL-HDE100 transmitter labeled TWISTED PAIR, then connect the
other end of the Category cable to the DL-HDE100 receiver labeled TWISTED PAIR
To ensure proper performance of the
UTP cabling at a minimum. Category 5e F/UTP may perform well up to a certain length but may not support power over
HDBaseT reliably longer distances.
For optimized performance use the following Liberty Wire and Cable branded cabling;
Category 6 plenum; 24-4P-P-L6SH
Category 6A plenum; 24-4P-P-L6ASH
Category 6 NON-plenum; 24-4P-L6SH
Category 6A NON -plenum; 24-4P-L6ASH
Connecting RS232 Control
RS232 or serial control signals can be transmitted through the DL-HDE100 using the RS232 connection ports on
he DL-HDE100 transmitter and receiver.
1
8
TIA/EIA-568B
P n 1
Or n e/Wh te
P n 2
Or n e
P n 3
Green/Wh te
P n 4
Blue
P n 5
Blue/Wh te
P n 6
Green
P n 7
Brown/Wh te
P n 8
Brown
DL-HDE100
, it is recommended that you use solid core, shielded Category 6
When using shielded category cabling ALWAYS...
....use shielded connectors
....properly ground the category cable
RS232 Wiring
Connect the controller or device RX signal to
TX on the DL-HDE100 extender. Connect the
controller or device TX signal to RX on the
DL-HDE100 extender.
Twisted Pair Wiring
Use TIA/EIA-568B wiring for Category 6
connection between send and receive
units.
DL-HD70 Owners Manual