12 - MATCH BETWEEN REMOTE CONTROLLER AND THE UNIT

The remote control can be addressed to use up to 4 different units installed in the same room.
You can get unified control by using a single remote control for all units or each remote control can be addressed to
its own unit, in order to control separately temperature, timer and all other functions.
UNIT
0
FACTORY STATE
1
2
3
PCB SETTING
• Disconnect the unit power supply and wait at least 60 seconds, mak-
ing sure that all the lamps go off.
• Remove the rear panel and the cover of the electrical box to access
the pcb.
• Set JP2 and JP3 as shown in the table.
• Close the cover of the electrical box and the rear panel.
• Reconnect the unit power supply.
REMOTE CONTROLLER SETTING
• Press the button
• Press the arrow
• Press the button
setting) at the bottom starts flashing.
• Press the arrow
• Confirm with the button
• Press
to exit the menu.
REMOTE CONTROL UNIT
11
for a few seconds.
until you visualize 06.
again for a few seconds: the number 0 (factory
to set 1, 2 or 3.
.
PCB
JP2=CLOSE JP3=CLOSE
JP2=OPEN JP3=CLOSE
JP2=CLOSE JP3=OPEN
JP2=OPEN JP3=APERTO