Argo ULISSE ECO 설치 매뉴얼
CONTENTS
1 - General precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 - Installation site selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4 - Dimensions and weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5 - Minimum operation and maintenance area . . . . . . . . . . . . . . . . . .4
6 - Tubing length and elevation difference limits . . . . . . . . . . . . . . . . .4
7 - Installation of outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8 - Wall installation (through a hole in the wall) . . . . . . . . . . . . . . . . . .7
10 - Remote control unit installation . . . . . . . . . . . . . . . . . . . . . . . . . .10
11 - Maintenance of the refrigerant circuit. . . . . . . . . . . . . . . . . . . . . .10
13 - Electrical wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R32, ua fluorinated greenhouse gas
with a global warming potential (GWP) of 675. Do not
release R32 into the atmosphere.
R32 (STANDARD): 0.750 kg / 0.506 Tonn. CO2 eq.
R32 (STANDARD + 2 m): 0.785 kg / 0.530 Tonn. CO2 eq.
R32 (STANDARD + 4 m): 0.820 kg / 0.554 Tonn. CO2 eq.
The unit contains R32, a slightly flammable gas.
Before installing the unit, read this installation manual and streactly follow all safety instructions.
Always contact an Argoclima Service Center.
Any repair must be performed by qualified personnel, following the instructions contained in the
manufacturer's technical manual.
IMPORTANT
Do not try to accelerate the defrosting process or to clean the appliance in different ways other than
those recommended by the manufacturer.
The unit has to be stored in a room that doesn't have any continuously operating ignition sources (for
example: open flames, an operating gas appliance or an operating electric heater).
Do not pierce or burn the unit.
Be aware that refrigerants do not have any odour.
This unit has to be installed, operated and stored in a room with a floor area larger than 6m
must be well ventilated.
IN CASE OF MAINTENANCE OF THE REFRIGERANT CIRCUIT
The installer must be in possession of the F-GAS certification without any integration.
The installer must have the appropriate equipment (vacuum pump and recuperator) certified for R32.
Power supply:
220 - 240 V ~ / 1 / 50 Hz
2
2
. The room