ACU-RITE SENC 150 설치 매뉴얼 - 페이지 7
{카테고리_이름} ACU-RITE SENC 150에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ACU-RITE SENC 150 8 페이지. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
ACU-RITE SENC 150에 대해서도 마찬가지입니다: 참조 매뉴얼 (20 페이지), 설치 매뉴얼 (4 페이지), 설치 매뉴얼 (6 페이지), 사용 설명서 (12 페이지)
SENC 150
Spar installation ...
•
Remove the bracket assembly from the reading
head, and the encoder from the spar.
•
Position the spar to the scribed lines and mark one
end mounting hole location to the knee.
•
Drill and tap location for a 1/4-20 x 1/2" deep.
.010" TIR of the axis travel or
1/4-20 x 5/8" FHCS
•
Temporarily fasten the spar to the knee at one end
with a 1/4-20 x 5/8" FHCS provided.
•
Align the top of the spar to the saddle travel.
•
Transfer punch the second mounting hole.
•
Remove the spar, drill and tap location for a
1/4-20 x 1/2" deep.
Leveling screws
(2) per
Leveling
block
Spacer (2)
Knee
•
Attach the spar with the leveling blocks and
spacers to the knee.
•
Align the front surface of the spar using the
leveling screws to aid with front surface alignment.
•
Align the top surface of the spar and secure in
place.
P.N. 385072-222 Ed B 11/05
Mark one end hole location
Align to within
top surface of ways
Saddle
Align to within .010" TIR
of the saddle axis travel
1/4-20 x 2" BHCS & *M6 x
.017 thk. washer (2)
Align to within .010" TIR
of the saddle axis travel
Installation Manual 385072-45
Encoder Installation Manual For: Vertical Knee Mill
Cross Feed Y Axis on Right Hand Side
M4 x 8mm SHSS
•
Insert and center the encoder in the spar from end
to end as done previously.
•
Tighten set screws to secure in place.
Reading head installation ...
Transfer punch mounting slot
locations to the back of the
saddle
•
With the axis at the center of travel, attach the
bracket assembly to the reading head.
•
Position the assembly to the saddle, and transfer
punch the two mounting slot locations.
•
Remove the assembly from the reading head, drill
and tap the locations for 1/4-20 x 1/2" deep.
1/4" Flat washer x .09" thk. (2)
•
Loosely attach the bracket assembly to the saddle.
3
Encoder
Flush side (1 & 2)
*1/4-20 x 1" BHCS (2)
Acu-Rite Companies Inc.