Replacing the cartridge
1) Unscrew the headshell from the tonearm
2) Unscrew the cartridge from the headshell, and disconnect the 4
wires to take off the cartridge as below:
•
White wire: Left channel, Positive pole
•
Blue: Left channel, Negative pole
•
Red: Right channel, Positive pole
•
Green: Left channel, Negative pole
3) Tightly screw the new cartridge to the headshell, and connect
the wires correctly using the information above.
4) Remember to adjust the counter weight stylus pressure and
anti-skate value according to the new cartridge specifications.
5) The full sound quality of the Argon Audio TT-4 can only be
achieved if the cartridge is correctly adjusted. If you are not well
acquainted with the adjustment of cartridges you are advised to
call upon the willing help of your Argon Audio dealer to
accomplish this task for you.