THE MONITOR INDICATES BLOCKAGE AT A SEED
MODULE FOLLOWING TEST AND EVEN AFTER CLEANING
Defected seed module.
Troubleshooting: insert a long stick inside the seed sensor. If LED gets dark for
a second: it works. If not: sensor is defected.
THE MONITOR INDICATES IRREGULAR SEED DROPS
WHEN SEEDER STOPPED
Seeds or seed fragments picked up accidentally by the air-flow are
detected by the seed sensor. Sensitivity was set too high – adjust higher
time limit to reduce sensitivity.
Sensor is defected
THERE IS NO SEED DETECTION AT A PROPERLY
WORKING SEEDER, TEST FINDS SEED MODULES, NO DUST
INDICATED
Small sized seeds at low rate seeding – adjustment to small seed size and
missing seed time interval to higher.
Module is defected, check it by blinking LED with a long stick inserted
inside.