Servicing the Blade Server
The chapter contains the following sections:
•
•
•
•
•
•
•
•
•
•
•
Drive Replacement
You can remove and install hard drives without removing the blade server from the chassis.
The drives supported in this blade server come with the drive sled attached. Spare drive sleds are not available.
A list of currently supported drives is in the specification sheets at this
URL:http://www.cisco.com/c/en/us/products/servers-unified-computing/ucs-b-series-blade-servers/datasheet-listing.html
Before upgrading or adding a drive to a running blade server, check the service profile in Cisco UCS Manager
and make sure the new hardware configuration will be within the parameters allowed by the service profile.
Caution
To prevent ESD damage, wear grounding wrist straps during these procedures.
Removing a Blade Server Drive
Step 1
Push the button to release the ejector, and then pull the hard drive from its slot.
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v3 and E7 v2 CPUs
Drive Replacement, on page 13
Removing a Blade Server Cover, on page 15
Internal Components, on page 16
Diagnostics Button and LEDs, on page 19
Installing a CMOS Battery, on page 20
Removing a CPU and Heat Sink, on page 20
Installing a New CPU and Heat Sink, on page 22
Installing Memory, on page 26
Installing a Virtual Interface Card Adapter, on page 32
Installing an Adapter Card, on page 33
3
C H A P T E R
13