Installing a Blade Server
a) Line up the four captive screws on the UCS Scalability Terminator with the holes on the front of the blade
module(s).
b) Push the UCS Scalability Terminator or UCS Scalability Connector into place.
c) Tighten the captive screws on the front of the UCS Scalability Terminator or the UCS Scalability Connector.

Server Configuration

Cisco UCS blade servers should be configured and managed using Cisco UCS Manager. For details, see the
Configuration Guide for the version of Cisco UCS Manager that you are using. The configuration guides are
available at the following URL:
http://www.cisco.com/en/US/products/ps10281/products_installation_and_configuration_guides_list.html

Powering Off a Blade Server Using the Power Button

Note
The front panel power button is disabled by default to ensure that servers are decommissioned through the
UCS Manager software before shutdown. If you prefer to shut down the server locally with the button, you
can enable front power-button control in UCS Manager.
Tip
You can also shut down servers remotely using Cisco UCS Manager. For details, see the Configuration Guide
for the version of Cisco UCS Manager that you are using. The configuration guides are available at the
following URL:
http://www.cisco.com/en/US/products/ps10281/products_installation_and_configuration_guides_list.html
Procedure
Step 1
If you are local to the server, check the color of the Power Status LED for each server in the chassis that you
want to power off.
• Green indicates that the server is running and must be shut down before it can be safely powered off. Go
• Amber indicates that the server is already in standby mode and can be safely powered off. Go to Step 3.
Step 2
If you previously enabled front power-button control through Cisco UCS Manager, press and release the
Power button, then wait until the Power Status LED changes to amber.
The operating system performs a graceful shutdown and the server goes to standby mode.
Caution
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v3 and E7 v2 CPUs
to Step 2.
To avoid data loss or damage to your operating system, you should always invoke a graceful
shutdown of the operating system.