Removing a Blade Server from the Chassis

Step 3
(Optional) If you are shutting down all blade servers in a chassis, disconnect the power cords from the chassis
to completely power off the servers.
Step 4
Remove the appropriate servers from the chassis.
Removing a Blade Server from the Chassis
You must power off the blade server or decommission it using Cisco UCS Manager before physically removing
the blade server from the chassis.
Procedure
Step 1
Turn off the blade server using either Cisco UCS Manager or the power button.
Step 2
If you are removing a UCS B460 M4 blade server, completely loosen the captive screws on the UCS Scalability
Connector and remove the connector by pulling it away from the two UCS B260 blade modules. If you are
removing a UCS B260 M4 blade server, you do not need to remove the UCS Scalability Terminator prior to
removing the UCS B260 M4 blade server.
Step 3
Completely loosen the captive screws on the front of the blade.
Step 4
Remove the blade from the chassis by pulling the ejector levers on the blade until it unseats the blade server.
Step 5
Slide the blade part of the way out of the chassis, and place your other hand under the blade to support its
weight.
Step 6
Once removed, place the blade on an antistatic mat or antistatic foam if you are not immediately reinstalling
it.
Step 7
If the blade server slot is to remain empty, reinstall the slot divider and install two blade server blanking
panels.

Server Troubleshooting

For general troubleshooting information, see the
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v3 and E7 v2 CPUs
12
Cisco UCS Manager Troubleshooting Reference
Installing a Blade Server
Guide.