AEMC instruments FlexProbe 24-3001 사용자 설명서 - 페이지 13

{카테고리_이름} AEMC instruments FlexProbe 24-3001에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AEMC instruments FlexProbe 24-3001 17 페이지. Flexible ac current probe

Find Quality Products Online at:
When using the FlexProbe
important to select the range that provides the
best resolution. Failure to do this may result in
measurement errors.
For best results, select the highest FlexProbe
output signal possible and the most sensitive
meter range for this output.
Make sure the DMM or measuring instrument can
accurately measure mV
DMM have poor resolution and accuracy when
measuring low mV
.
AC
For best accuracy, center the FlexProbe
the conductor to be measured.
To increase the sensitivity or measure on low cur-
rents, the FlexProbe
®
times around the conductor. Remember to divide
your reading by the number of turns for the actual
measurement (See Figure 1).
The overall measurement accuracy is the sum of
the FlexProbe
accuracy and the displaying instru-
®
ment accuracy.
The FlexProbe
may be doubled around the con-
®
ductor to be measured to double the output. (See
DMM while measuring 250A
GlobalTestSupply
www.
with a meter, it is
®
®
. Certain inexpensive
AC
®
around
may be wrapped several
.)
AC
.com