6.3.5.2
Parameter settings and defaults
CF – Close Fast Speed – Default setting is 60. Range is 1-100
CS – Close Slow Speed – Default setting is 20. Range is 1-100
SS – Close slow start – Default setting is 20. Range 1-100.
CFH – Close Fast Heavy Door Speed – default is 20. Range is 1-100
PL – Open slow Start speed – Default is 20. Range is 1-100
OS – Open Slow speed – Default is 20. Range is 1-100.
OF – Open Fast speed – Default is 60. Range is 1-100.
N – Nudging speed – Default is 10. Range is 1-100
CCL – Closing Force – Default is 30. Range is 1-100
DLF – Door Locking Force – Default is 10. Range is 1-100
DEC – Deceleration Rate – Default is 10. Range is 1-100.
ACC – Acceleration Rate – Default is 10. Range is 1-100
FDEC – Reversal Deceleration Rate – Default is 10. Range is 1-100.
Motor Direct – Used for swapping open/close direction. 1 is forward 2 is reverse
Input voltage – Default is 110. Range is 24 – 320.

6.3.6 Load Defaults menu

Selecting Load Defaults sets all parameters to their default settings. Refer to section 6.3.5.2 for default
settings.

6.3.7 Diagnostic Menu

VBUS – Displays the current voltage of the 54P input
DRIVE – The drive to the motor is pulse width modulate. This number reflects the percentage of
drive to the motor. 0% will be no power to the motor and 100% will be max drive.
16s – This is the present count of the 16 second stall timer. Should an open or close cycle time
out the door board will stall the motor until the open/close command is cycled off/on.
TEMP – Displays the current temp in °C/°F of the output driver transistors.
MOTOR – Displays the current amperage to the motor.
SPEED – Displays the current speed of the open or close cycle.
CYCLE – Displays the number of cycles the door board has performed since manufacture. One
cycle is an open and close.
ECI 1000-U LCD Installation Manual
ECI Model 1000N
(C) 2015 ECI, Inc.
VBUS :
xx.xV
DRIVE:
TEMP :
MOTOR:
Cycle:
xxxxx
Figure 3 - Diagnostic Menu
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
www.eciamerica.com
xx%
16s
xxC/xxxF
x.xA
(ESC)
P a g e
| 11