Toshiba Carrier MMC-AP0181H2UL 설치 매뉴얼 - 페이지 5

{카테고리_이름} Toshiba Carrier MMC-AP0181H2UL에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Toshiba Carrier MMC-AP0181H2UL 18 페이지. Air conditioner (multi type)

Ceiling type
2
Removing wire guard
Remove the screws (2 pcs.) which are fixing the
wire guard.
Remove the clamp fixing screws and remove the
wire guard.
Clamps
Screw
CAUTION
Attach back the wire guard once indoor unit is installed.
Remove the 2 screws fixing the wire guard and hung the
wire guard with the clamps during a service.
Wire guard
7-EN
Installation Manual
3
Removal of side panel
After removing the side panel fixing screws (1
each at right and left), slide the side panel forward
and then remove it.
Protector
Side panel
Level louver
Slide forward.
4
Removal of protective vinyl
Peel out the protective vinyl on the level louver.
5
Removal of protector
Remove the protector (1 pcs.) of the fan.
(AP024 only)
Ceiling type
4

Installation

REQUIREMENT
Strictly comply with the following rules to prevent damage of the indoor units and human injury.
• Do not put a heavy article on the indoor unit. (Even units are packaged)
• Carry in the indoor unit as it is packaged if possible. If carrying in the indoor unit unpacked by necessity, use buffering
cloth or other soft cloth to not damage the unit.
• To move the indoor unit, hold the hooking metals (4 positions) only.
Do not apply force to the other parts (refrigerant pipe, drain pan, foamed parts, or resin parts).
• Carry the package by two or more persons, and do not bundle it with plastic band at positions other than specified.

External view

1.5" (39)
Upper pipe draw-out port (knockout)
Hole for remote control wires (knockout)
Conduit hole
(Hole for power supply cable. knockout)
3.3" (84)
Refrigerant pipe
Left drain size
(Liquid side ØC)
Refrigerant pipe (Gas side ØD)
B (Hanging position)
5.3" (135)
Hanging bolt
Ceiling surface
Pipe hole on wall
Unit
(Ø3.9" (100) hole)
A
– 4 –
Installation Manual
2.0" (52)
6.6" (167)
8.5" (216)
Pipe draw-out port
8.3" (210)
(knockout)
4.3" (110)
3.0" (76)
Drain port VP20
(Inner dia. Ø1.0" (26), hose
4.1" (105)
attached)
Drain pipe
connecting
port
3.0" (75)
3.8" (97)
5.7" (146)
Hole for remote control wires
13.7" (347)
Conduit hole
12.2" (311)
(knockout)
10.3" (262)
3.3" (84)
Hole for power supply cable
Outside air take-in port (Duct sold separately)
Knockout hole Ø3.6" (92))
Wireless sensor mounting section
Model MMC-
A
B
35.8"
33.7"
AP018
(910)
(855)
46.5"
44.3"
AP024
(1180)
(1125)
62.8"
60.6"
AP036, AP042
(1595)
(1540)
Unit: in (mm)
Left drain pipe
draw-out port
(knockout)
Unit: in (mm)
C
D
Ø1/4"
Ø1/2"
(6.4)
(12.7)
EN
Ø3/8"
Ø5/8"
(9.5)
(15.9)
8-EN