Dimplex BLF74 서비스 매뉴얼 - 페이지 6

{카테고리_이름} Dimplex BLF74에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dimplex BLF74 16 페이지. Section 10309 manufactured electric fireplaces
Dimplex BLF74에 대해서도 마찬가지입니다: 사용자 설명서 (3 페이지)

Dimplex BLF74 서비스 매뉴얼

WIRING DIAGRAM

120V Installations
1. Regular installation
attach N and L2 together
240V Installations
1. Regular installation
attach Neutral and L2 to
the panel
6
VOLTAGE SELECTOR SWITCH
2
THERMAL
6
CUTOUT
4
L1
1
5
3
Different Heat Control Options
2. For No Heat installations
N
leave L2 unconnected with
a wire connector on the end
L2
VOLTAGE SELECTOR SWITCH
2
THERMAL
CUTOUT
6
4
L1
1
5
3
Different Heat Control Options
2. For No Heat installations
leave L2 unconnected with
a wire connector on the end
L2
CONTROL PCB
L
L1
RL3
RL2
RL1
N
N
N
See Options
Below
3. For installation with a
N
Heat Disconnect Switch
L2
CONTROL PCB
L
RL3
RL2
RL1
N
N
N
3. For installation with a
Heat Disconnect Switch
L2
N
L2
Wall On/Off Switch
L1
240 V~ / 60 HZ
Power Supply
(Breaker Panel)
N
See Options
Below
L2
L2
L2
Wall On/Off
Switch
www.dimplex.com