Fitting Instruction
1. Identify the most appropriate position for the shower chair ensuring the product is at a comfortable
height and distance for showering.
NOTE: When determining the most appropriate position for the shower chair ensure the legs are
fully extended, level and resting on the shower tray. The leg extension height can be adjusted by
removing the locking pins. Once the ideal height has been determined re-insert the locking pins to
secure the legs in position (See Fig.1).
2. The product can be folded upwards for more convenient storage so please ensure there is sufficient
space above the fixing position to allow for this.
3. Place the shower chair in the desired position on the wall and using the hole centres located on the wall
bracket as a template, mark the screw fixing positions on the wall surface ensuring the product is level.
ALL FIXING HOLES MUST BE USED (See Fig.1).
4. Drill the holes in the marked positions using a masonry drill. If the product is to be fitted onto a
ceramic tiled wall, a ceramic drill bit should be used.
5. Insert wall plugs (if applicable) flush to the surface of the wall. If fitting to a tiled surface, the wall plugs
should be inserted below the surface of the tile to avoid cracking.
6. Insert the screws through the holes located on the wall bracket and screw to the wall.
NOTE: Do not use countersink screws. Do not enlarge fixing holes. This can reduce the strength of
the frame and invalidate the safe working load stated.
7. Always check the shower chair is securely fastened to the wall before use.
To secure the pad to the seat
use the retainers provided.
If the seat pad is removed, fill the
holes with the plastic bungs provided.
Additional Information
Maximum safe working load for the shower seat is 158kg when fitted to solid brick, concrete block walls or
similarly strong materials offering appropriate support for the maximum safe working load.
NOTE: Lightweight thermal blocks, aerated hollow brickwork or prefabricated partition walls will
reduce the maximum safe working load of this product.
For details of the other items in the Croydex range please visit our website: www.croydex.com
Croydex Ltd, Central Way, Andover, Hants, SP10 5AW, UK
Tel: +44 (0) 1264 365881
Fax: +44 (0) 1264 356437
Fig.1
2
Make sure all fixing
holes are used.
Remove locking pins for
leg adjustment. Re-insert
once ideal leg height is
determined.
Lift collar on leg to level
the seat accordingly.
S&H 039 R01