{카테고리_이름} Aeon Labs AEO_SES3_EU에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aeon Labs AEO_SES3_EU 5 페이지. Inline smart energy switch

Load will be closed when the Current overrun (US: 15.5A, other country: 16.2A) and the time more than 2 minutes (0=disabled, 1=enabled).
Value
0
Active Overload Protection (Default)
1
Deactivate Overload Protection
Output Load Status (Parameter Number 20, Parameter Size 1)
Configure the output load status after re‐power on.
Value
0
1
2
Notification on Status Change (Parameter Number 80, Parameter Size 1)
Defines the automated status notification of an associated device when status changes (0=nothing, 1=hail CC, 2=basic CC report).
Value
0
1
2
Configure the state of red LED (Parameter Number 81, Parameter Size 1)
Value
0
The LED will follow the status (on/off) of its load. (Default)
1
When the state of Switch's load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action.
Enables/disables parameter 91/92 (Parameter Number 90, Parameter Size 1)
Value
0
Enabled parameter 91/92 (Default)
1
Disabled parameter 91/92
Minimum Change to send Report (Watt) (Parameter Number 91, Parameter Size 2)
The value represents the minimum change in wattage for a Report to be sent .
Value
0 — 32000
The value represents the minimum change in wattage. (Default 25)
Minimum Change to send Report (%) (Parameter Number 92, Parameter Size 1)
The value represents the minimum change in wattage Percent for a report to be sent. (Valid values 0‐100)
Value
0 — 100
The value represents the minimum change in wattage Percent. (Default 5)
Set 101‐103 to default (Parameter Number 100, Parameter Size 1)
Value
0
1
Report type send in Reporting Group 1 (Parameter Number 101, Parameter Size 4)
Defines the type of report sent for the Reporting Group 1.
Value
2
4
8
Report Type send in Reporting Group 2 (Parameter Number 102, Parameter Size 4)
Defines the type of report sent for the Reporting Group 2.
last status (Default)
always on
always off
nothing (Default)
hail
basic CC report
set to default (Default)
nothing
Multisensor Report
Meter Report for Watt
Meter Report for kWh (Default)