Dinel HLM-35N-SV 사용 설명서 - 페이지 8
{카테고리_이름} Dinel HLM-35N-SV에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dinel HLM-35N-SV 20 페이지. Hydrostatic level meters
In case of use cable with capillary connect the positive pole (+U) of the power supply
to the red wire RD, or connector pin no. 1, the negative pole (0 V) to the blue wire BU, or
connector pin no. 3, and the output voltage (U
4. Connection diagrams are provided in the figures below.
In case of use cable without capillary connect the positive pole (+U) of the power supply
to the brown wire BR, or connector pin no. 1, the negative pole (0 V) to the blue wire BU, or
connector pin no. 3, and the output voltage (U
4. Connection diagrams are provided in the figures below.
Level meter connection with current output
(X) – Connector terminal numbers
0 V (3)
Level meter connection with current output
(X) – Connector terminal numbers
0 V (3)
U
(4)
out
8
BR (1)
RD
BU (3)
+U (1)
BR (1)
RD
BK (4)
BU (3)
+U (1)
) to the black wire BK, or connector pin no.
out
) to the black wire BK, or connector pin no.
out
Cable wire colours with
a pressed connector:
BR – brown
BU – blue
Cable wire colours
with capillary:
RD – red
BU – blue
---- – shielding
Cable wire colours with
a pressed connector:
BR – brown
BK – black
BU – blue
Cable wire colours
with capillary:
RD – red
BU – blue
BK – black
---- – shielding
HLM–35