Aeotec Water Sensor 7 Pro 빠른 시작 매뉴얼 - 페이지 6
{카테고리_이름} Aeotec Water Sensor 7 Pro에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aeotec Water Sensor 7 Pro 8 페이지. Water sensor
Aeotec Water Sensor 7 Pro에 대해서도 마찬가지입니다: 매뉴얼 (3 페이지), 사용자 설명서 (9 페이지), 사용자 설명서 (13 페이지), 사용자 설명서 (14 페이지), 사용자 설명서 (9 페이지)
This parameter defines if the alarm cancellation event is reported.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 16: Minimum Temperature change to report
This value defines the minimum change of temperature to cause an unsolicited report of temperature to the
central controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However,
periodic reports, managed by configuration parameter 18, may still be active.
Size: 1 Byte, Default Value: 20
Setting
0
1 - 100
Parameter 17: Minimum humidity change to report
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central
controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However,
periodic reports, managed by configuration parameter 18, may still be active.
Size: 1 Byte, Default Value: 5
Setting
0
1 - 20
Parameter 18: Periodic Reports
This parameter defines the time interval to send an unsolicited report.
If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on
temperature/humidity changes, managed by configuration parameters 16 and 17, may still be active.
Size: 2 Byte, Default Value: 43200
Setting
0
900 - 65535
Parameter 255: Reset Parameter
This parameter helps reset configuration parameters and the device to factory defaults
Size: 4 Byte, Default Value: 0
Setting
1 - 1431655764
(0x55555554)
1431655765
Technical Data
Description
Do not send Report
Send Report
Description
Disabled
1/10 degree
Description
Disabled
%
Description
Disabled
Seconds
Description
Reset all Parameter settings to their default settings.
Completely factory reset sensor and send device reset locally
notification.