This parameter defines if the alarm cancellation event is reported.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 16: Minimum Temperature change to report
This value defines the minimum change of temperature to cause an unsolicited report of temperature to the
central controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However,
periodic reports, managed by configuration parameter 18, may still be active.
Size: 1 Byte, Default Value: 20
Setting
0
1 - 100
Parameter 17: Minimum humidity change to report
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central
controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However,
periodic reports, managed by configuration parameter 18, may still be active.
Size: 1 Byte, Default Value: 5
Setting
0
1 - 20
Parameter 18: Periodic Reports
This parameter defines the time interval to send an unsolicited report.
If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on
temperature/humidity changes, managed by configuration parameters 16 and 17, may still be active.
Size: 2 Byte, Default Value: 43200
Setting
0
900 - 65535
Parameter 255: Reset Parameter
This parameter helps reset configuration parameters and the device to factory defaults
Size: 4 Byte, Default Value: 0
Setting
1 - 1431655764
(0x55555554)
1431655765

Technical Data

Description
Do not send Report
Send Report
Description
Disabled
1/10 degree
Description
Disabled
%
Description
Disabled
Seconds
Description
Reset all Parameter settings to their default settings.
Completely factory reset sensor and send device reset locally
notification.