Aeotec Water Sensor 7 Pro 사용자 설명서 - 페이지 12

{카테고리_이름} Aeotec Water Sensor 7 Pro에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Aeotec Water Sensor 7 Pro 14 페이지. Water sensor
Aeotec Water Sensor 7 Pro에 대해서도 마찬가지입니다: 매뉴얼 (3 페이지), 빠른 시작 매뉴얼 (8 페이지), 사용자 설명서 (9 페이지), 사용자 설명서 (13 페이지), 사용자 설명서 (9 페이지)

Aeotec Water Sensor 7 Pro 사용자 설명서
Product ID 1
Product ID 2

Version

4.6
Parameter
Z-Wave Protocol Library Type 0x03
Z-Wave Protocol Version
Z-Wave Protocol Sub Version
Firmware 0 Version
Firmware 0 Sub Version
Hardware Version
Number of firmware targets

Association Group Info

4.7
Root product
ID
Name
Node count Profile
1
Lifeline
5
2
Control
5
3
Alarm
5
4
Tamper
5
5
Tilting
5

Notification

4.8
Notification Type
Access Control
0x06
Home Security
0x07
0x00

Binary Sensor

4.9
Sensor Type
Door/Window
0x0A
AEOTEC User Manual
0x00
0x0C
Value
0x07
0x0C
0x01 [Z-Wave Chip Firmware Version]
0x00 [Z-Wave Chip Firmware Sub Version]
0x01
0x00
Function
Product Reset Locally Notification:
Issued when Factory Reset is performed.
Battery Report:
Issued when battery becomes low.
Sensor Binary Report:
Issued when tilt angle is changed
Issued when sensor state is changed.
General: Lifeline
Notification Report [Type=0x06; Event=0x16]:
(0x0001)
Issued when sensor state is changed to be Open Status.
Notification Report [Type=0x06; Event=0x17]:
Issued when sensor state is changed to be Close Status.
Notification Report [Type=0x07; Event=0x03]:
Issued when tamper is tripped
Central Scene Notification:
Issued when the external dry contact is activated
Control: Key01
Basic Set:
(0x2001)
Control devices when a magnet or external dry contacts trips
Notification Report:
Notification:Access
Sends out alarm message when a magnet or external dry sensor
Control (0x7106)
trips
Notification:home
Notification Report:
Security (0x7107)
Sends alarm messages when tamper is tripped
Control: Key02
Basic Set:
(0x2002)
Control devices when tilting sensor trips
Notification Events
Window/Door is open
Window/Door is closed
Tamper Removed
State idle
Sensor Value
0x00 / 0xFF
Description
0x16
Open Status.
0x17
Close Status.
0x03
Tamper removed
0x00
Going to idle
Description
Door/Window State