Removing the Out-of-Balance Switch

The Out-of-Balance Switch is located on the inside surface of the feature panel.
1.
Reach into the bottom of the plastic protective cover of the Out-of-Balance Switch and discon-
nect the wiring harness plug from the switch terminals.
2.
Remove the hex-head screw on the outside surface of the feature panel. (Fig. 12)
3.
Slide the Out-of-Balance Switch so the tabs of the mounting bracket disengage from the key
slots as show in Figure 12 and remove the switch assembly.
NOTE: The Service Replacement Out-of-Balance Switch is equipped with a clear
plastic protective cover. This MUST be installed with the switch. (Fig. 13)
Fig. 12
SLIDE TO LEFT TO
DISENGAGE TABS
Servicing the Catalyst Cleaning Action™ Recirculation System
Figure 17 illustrates the various components of the Catalyst Cleaning Action™ recirculation system.
These components are:
Pump
Diverter Valve
Recirculation Pressure Dome
Recirculation Pressure Switch
Recirculation Spray Inlet (part of Tub Ring)
SCREW
22