Whirlpool 4322658A 매뉴얼 - 페이지 25

{카테고리_이름} Whirlpool 4322658A에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool 4322658A 48 페이지. In-door ice system

DIAGNOSTICS & TROUBLESHOOTING

OPTICS DIAGNOSTICS MODE

Diagnostics are used to determine whether the
optics circuits are operating properly. If the
optics circuits are malfunctioning, the ice maker
will not operate.
The optics system consists of an emitter board
and a receiver board. The emitter board trans-
mits a beam of infrared light that is detected
by the receiver. If the beam of light is inter-
rupted, the ice maker will not operate.
FLOW CHART TO
DETERMINE OPTICS
BOARD DESIGN
Wait 5 minutes and
use 2002 Design Optics
Mode on Page 5-4.

DIAGNOSTICS

Proceed to 2002
Design Optics
Mode on Page 5-4.
The optics system can have one of two types
of optics board designs installed: the original
design, or the 2002 design.
Use the following flow chart to determine which
of the board designs are installed. Once this is
determined, you will be directed to perform the
appropriate optics diagnostics procedure.
Close the freezer
door for a minimum
of 1 minute.
Open the freezer
LED is flashing 2
Yes
pulses repeated.
Hold in the freezer
light switch.
LED is flashing at 1 second
intervals indicating a 5 minute
Yes
"harvest" mode.
Proceed to Original
Design Optics
Mode on Page 5-2.
5-1
door.
No
No