Whirlpool  WED9051YW 설치 지침 매뉴얼 - 페이지 16

{카테고리_이름} Whirlpool  WED9051YW에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool  WED9051YW 20 페이지. Installation guide
Whirlpool  WED9051YW에 대해서도 마찬가지입니다: 사용 및 관리 매뉴얼 (20 페이지)

Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
Use the following "Vent System Charts" to determine type
of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in "Vent System Charts." Exhaust systems longer than those
specified will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
The "Vent System Charts" provide venting requirements that
will help achieve best drying performance.
Standard Vent System Chart
Type
Number of
of vent
90° elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
Long Vent System Chart*
Type
Number of
of vent
90° elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
*For Model WED9051Y only.
NOTE: Bottom exhaust installations have a 90º turn inside the
dryer. To determine maximum exhaust length, add one 90º turn
to the chart.
16
Box/louvered
Angled
hoods
hoods
58 ft. (17.7 m)
64 ft. (20 m)
54 ft. (16.5 m)
48 ft. (14.6 m)
44 ft. (13.4 m)
38 ft. (11.6 m)
35 ft. (10.7 m)
29 ft. (8.8 m)
27 ft. (8.2 m)
21 ft. (6.4 m)
Box/louvered
Angled
hoods
hoods
130 ft. (39.6 m)
129 ft. (39.3 m)
125 ft. (38.1 m)
119 ft. (36.3 m)
115 ft. (35.1 m)
109 ft. (33.2 m)
106 ft. (32.3 m)
100 ft. (30.5 m)
98 ft. (29.9 m)
92 ft. (28.0 m)

INSTALL VENT SYSTEM

1.
Install exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
2.
Connect vent to exhaust hood
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90° turns. Use clamps to seal
all joints. Do not use duct tape, screws, or other fastening
devices that extend into interior of vent to secure vent,
because they can catch lint.
12" min.
(305 mm)
12" min.
(305 mm)