Whirlpool Duet Steam WED94HEX 설치 지침 매뉴얼 - 페이지 9

{카테고리_이름} Whirlpool Duet Steam WED94HEX에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool Duet Steam WED94HEX 16 페이지. Electronic dryer
Whirlpool Duet Steam WED94HEX에 대해서도 마찬가지입니다: 치수 매뉴얼 (2 페이지), 사양 (1 페이지), 사용 및 관리 매뉴얼 (40 페이지)

Whirlpool Duet Steam WED94HEX 설치 지침 매뉴얼
3. Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
A
B
C
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. ¾" (19 mm) UL listed strain relief
D. Center, silver-colored terminal block screw
E. Neutral ground wire
F. Neutral wire (white or center wire)
4. Connect the other wires to outer terminal block screws. Tighten
screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to
"Venting Requirements."
4-wire connection: Direct wire
IMPORTANT: A 4-wire connection is required for mobile homes and
where local codes do not permit the use of 3-wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can
be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving bare
ground wire at 5" (127 mm). Cut 1
wires. Strip insulation back 1" (25 mm). Shape ends of wires into a
hook shape.
D
E
F
1
/
" (38 mm) from 3 remaining
2
When connecting to the terminal block, place the hooked end of the
wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
1. Remove center, silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and place the hooked end
(hook facing right) of the neutral wire (white or center wire) of direct
wire cable under the center screw of the terminal block. Squeeze
hooked ends together. Tighten screw.
A
B
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center, silver-colored terminal block screw.
B. Center, silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. ¾" (19 mm) UL listed strain relief
3. Connect ground wire (green or bare) of direct wire cable to
external ground conductor screw. Tighten screw.
A
B
C
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cable
C. ¾" (19 mm) UL listed strain relief
D. Center, silver-colored terminal block screw
E. Neutral ground wire
F. Neutral wire (white or center wire)
4. Place the hooked ends of the other direct wire cable wires under
the outer terminal block screws (hooks facing right). Squeeze
hooked ends together. Tighten screws.
C
D
E
D
E
F
9