4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
"Venting Requirements."
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do
not permit connecting cabinet-ground conductor to neutral wire.
1. Remove center, silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white
or center wire) of power supply cord/cable under center, silver-
colored terminal block screw. Tighten screw.
A
A. External ground conductor screw
B. Center, silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. ¾" (19 mm) UL listed strain relief
F. Grounding path determined by a qualified electrician
3. Connect the other wires to outer terminal block screws. Tighten
screws.
4. Tighten strain relief screws.
5. Connect a separate copper ground wire from the external ground
conductor screw to an adequate ground.
Venting Requirements
B
Use a heavy metal vent.
Do not use a plastic vent.
C
Do not use a metal foil vent.
Failure to follow these instructions can result in death
D
or fire.
E
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
F
of a building.
If using an existing vent system
■
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
■
Replace any plastic or metal foil vent with rigid heavy metal
vent or flexible metal vent.
■
Review vent system chart. Modify existing vent system if
necessary to achieve the best drying performance. Only rigid or
flexible metal vent shall be used for exhausting.
If this is a new vent system
Vent material
■
Use a heavy metal vent. Do not use plastic or metal foil vent.
■
4" (102 mm) heavy metal exhaust vent and clamps must be
used.
4" (102 mm) heavy metal exhaust vent
Vent products can be purchased from your dealer or by calling
Whirlpool Service. For more information, see the "Assistance or
Service" section.
Rigid metal vent
■
For best drying performance, rigid metal vents are
recommended.
■
Rigid metal vent is recommended to avoid crushing and kinking.
VENTING
WARNING
Fire Hazard
11