Whirlpool UXT3030AY 설치 지침 및 사용 및 관리 매뉴얼 - 페이지 9

{카테고리_이름} Whirlpool UXT3030AY에 대한 설치 지침 및 사용 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool UXT3030AY 28 페이지. 30" (76.2 cm) and 36" (91.4 cm) range hood
Whirlpool UXT3030AY에 대해서도 마찬가지입니다: 설치 지침 및 사용 및 관리 설명서 (32 페이지), 설치 지침 및 사용 및 관리 매뉴얼 (36 페이지)

Whirlpool UXT3030AY 설치 지침 및 사용 및 관리 매뉴얼
2. Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
A
A. Keyhole slot
3. Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown.
A. Drill pilot hole.
4. Install the 4 - 4.5 mm x 13 mm mounting screws in pilot
holes. Leave about ¹⁄₄" (6.4 mm) space between screw heads
and cabinet to slide range hood into place.
5. For roof installations, remove the top rectangular vent
knockout. For wall installations, remove the rear rectangular
vent knockout.
A. Top rectangular vent knockout
B. Rear rectangular vent knockout
A
¹⁄₄"
(6.4 mm)
A
B
6. Install the 3¼" x 10" (8.3 x 25.4 cm) vent damper. Attach to
range hood with the 3.5 x 9.5 mm screws provided and
remove tape from damper flap.
NOTE: The 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent
damper can be installed up to 1" (2.5 cm) on either side of
the hood center to accommodate off center ductwork.
A
D
B
A. Vertical damper
B. 3.5 x 9.5 mm screws
C. Vent knockouts
D. Horizontal damper
If a vent damper is installed with a wall cap with damper,
check that they do not interfere with each other. Remove
the vent connector damper flap if they interfere.
Damper Flap Removal for 3¼" x 10" (8.3 x 25.4 cm) Vent
Connector
1. Bend retainer wire out of damper flap catch tab.
B
A
H
G
F
A. Retainer wire
B. Damper flap wire guide
C. Plastic end caps
D. Stop tabs
2. Slide retainer wire to the side to allow one end of retainer wire
to come out of the damper flap wire guide and plastic end
cap.
3. Lift end of retainer wire and slide it out of the other damper
flap wire guide and plastic end cap to remove.
4. Push the small end of the plastic end caps out of vent
connector housing.
5. Lift the damper flap out of the vent connector housing.
6. Remove the foam from the stop tab.
7. Bend the stop tabs so they are flush with the damper side
walls.
8. Discard the retainer wire, plastic end caps, damper flap and
the foam.
B
C
C
E
E. Vent connector housing
F. Foam
G. Damper flap catch tab
H. Damper flap
D
9