Whirlpool UXW6536BSS 설치 지침 및 사용 및 관리 매뉴얼 - 페이지 8

{카테고리_이름} Whirlpool UXW6536BSS에 대한 설치 지침 및 사용 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Whirlpool UXW6536BSS 28 페이지. 30" and 36" (76.2 and 91.4 cm) wall-mount canopy range hood
Whirlpool UXW6536BSS에 대해서도 마찬가지입니다: 사용 및 관리 매뉴얼 설치 지침 (28 페이지)

Whirlpool UXW6536BSS 설치 지침 및 사용 및 관리 매뉴얼
2. Measure from the bottom of the air deflector to the bottom
of the hood outlet.
B
D
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
3. Cut the duct to the measured size "X."
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over the exhaust
outlet from the hood.
7. Reassemble the air deflector to the duct cover bracket
with the 4 assembly screws.
8. Seal connections with vent clamps.

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
a UL listed or CSA approved ¹⁄₂" (12.7 mm) strain relief.
8
A
C
X
D. Vent duct
E. Exhaust outlet
A. Knockout
B. Terminal box cover
C. Terminal box screws (7)
4. Run home power supply cable through strain relief
into terminal box.
G
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-green ground wires
G. Terminal box
5. Use UL listed wire connectors and connect black
wires (C) together.
6. Use UL listed wire connectors and connect white
wires (E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
C
B
A
A
B
C
D
E
F