Whirlpool UXW6536BSS Інструкція з монтажу та інструкція з експлуатації та догляду - Сторінка 8
Переглянути онлайн або завантажити pdf Інструкція з монтажу та інструкція з експлуатації та догляду для Вентиляційна витяжка Whirlpool UXW6536BSS. Whirlpool UXW6536BSS 28 сторінок. 30" and 36" (76.2 and 91.4 cm) wall-mount canopy range hood
Також для Whirlpool UXW6536BSS: Посібник з експлуатації та догляду Інструкція з монтажу (28 сторінок)
2. Measure from the bottom of the air deflector to the bottom
of the hood outlet.
B
D
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
3. Cut the duct to the measured size "X."
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over the exhaust
outlet from the hood.
7. Reassemble the air deflector to the duct cover bracket
with the 4 assembly screws.
8. Seal connections with vent clamps.
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
a UL listed or CSA approved ¹⁄₂" (12.7 mm) strain relief.
8
A
C
X
D. Vent duct
E. Exhaust outlet
A. Knockout
B. Terminal box cover
C. Terminal box screws (7)
4. Run home power supply cable through strain relief
into terminal box.
G
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-green ground wires
G. Terminal box
5. Use UL listed wire connectors and connect black
wires (C) together.
6. Use UL listed wire connectors and connect white
wires (E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
C
B
A
A
B
C
D
E
F