AER AG 82 사용자 설명서 - 페이지 5
{카테고리_이름} AER AG 82에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AER AG 82 9 페이지. Active monitor
3. Controls and connections
1) ground
2) power
3) clip
4) volume
5) treble
6) bass
7) level
8) aux in
9) level
10) mic in
11) level
12) line in
13) phantom power 9V 9V phantom power indicator - option – default setting: not activated
14) pre EQ
15) post EQ
16) power on
2
3
1
4
signal ground/protective ground disconneting switch
on/off status indicator
overload indicator
master level control
treble frequency level control
bass frequency level control
aux in level control
stereo input for additional signal sources (e.g. CD-player),
Cinch/RCA-sockets (white = left channel, red = right channel)
mic in level control
signal input - combo socket for 6.3 mm mono jackplug and
XLR male connectors (symmetrical, 48V phantom power)
line in level control
signal input - 6.3 mm mono jack socket,
factory provided phantom power not activated
insert pre equalizer, 6.3 mm stereo jack socket,
tip = send, ring = return,
insert post equalizer, 6.3 mm stereo jack socket,
tip = send, ring = return
power on/off switch with mains socket and fuse holder
(ref. to technical data: mains fuse)
5
6
7
8
14
15
9
10
11
16
= off
master
aux in
mic in
line in
insert
12
13
= on
eq
5