Septic Tank Monitoring

The diagram below shows the typical setup for septic tank monitoring. The VersAlarm™ I/O is shown in two locations to
demonstrate the most typical options for septic tank monitoring. The alarm float switch is connected to the sensor input for high
water indication. If water level is not high enough to activate the alarm float switch, then the top cover of the enclosure will be
green. If the alarm float switch is activated, then the top cover of the enclosure will flash red and the buzzer will annunciate.
The alarm condition will stay on until the alarm float switch is deactivated. If the silence pushbutton is pressed during an alarm
condition, then the top cover of the enclosure will turn solid red and the buzzer will silence. The silence condition will reset when
the alarm float switch deactivates. If the alarm is in silence mode for longer than 24 hours, the alarm will reactivate.
1) Indoor Application - The first option shows the VersAlarm™ I/O mounted in the utility room. The alarm float switch will need
splicing for the additional wire length. A second common indoor installation method is mounting the alarm in the garage
(not shown).
2) Outdoor Application - The second option is to mount the VersAlarm™ I/O to a post in the ground next to the septic tank. This
option would require a shorter alarm float switch cable length and running the power mains out to the alarm.
Septic
Alarm
to
Float
Drain Field
Pump
Switch
2
VersAlarm™ I/O
VersAlarm™ I/O | USER GUIDE
Alderon Industries™ - Leading Edge Control Products | 11