Clarke 2092500 운영 및 유지보수 지침 매뉴얼 - 페이지 12
{카테고리_이름} Clarke 2092500에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke 2092500 17 페이지. 150l engine driven air compressor
SYMPTOM
Compressor
constantly 'on
load' and
cannot attain
the working
pressure
required.
Compressor
becomes too
hot.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
PROBABLE CAUSE
Suction filter blocked.
Leak between compressor
block and air receiver leaks in
or near air receiver.
Valves blocked by dirt, paint,
dust or choked up.
Inspection cover or drain plug
leaking.
Pressure gauge defective
Unit too small in relation to air
consumption.
Compressor worn.
Insufficient ventilation.
Oil level too low (check 2 or
3 minutes after stopping.
Fault in valves (machine not
stopping).
Blown head gasket (machine
not stopping).
Dirt on cooling fins or suction
filter.
Unit working at too high a
pressure.
Not fully unloading
Load genie partly blocked.
REMEDY
Clean / Change filter.
Tighten connection and
repair leak.
Contact Clarke Service
Department
Empty air receiver and
change seals/plugs.
Change pressure gauge.
Use a larger capacity
compressor
Have compressor
overhauled or replace it.
See that sufficient air is
supplied to flywheel or fan
of compressor and that
hot air is properly vented.
Fill with oil
Contact Clarke Service
Department
Contact Clarke Service
Department
Clean cooling fins and
suction filter.
Contact Clarke Service
Department
Contact Clarke Service
Department
Contact Clarke Service
Department
12